Pulsed field ablation for atrial tachycardia originating from left atrial appendage in children: a case report

  • LIU Fuqiang ,
  • WANG Chuan ,
  • DUAN Hongyu ,
  • LI Yifei ,
  • MA Fan ,
  • WANG Fang ,
  • ZHOU Kaiyu ,
  • HUA Yimin
Expand
  • 1. The Division of Pediatric Cardiology, West China Second University Hospital of Sichuan University, Chengdu 610041, Sichuan, China
    2. Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital of Sichuan University, Chengdu 610041, Sichuan, China

Received date: 2025-07-17

  Accepted date: 2025-09-10

  Online published: 2025-09-29

Abstract

A trial tachycardia (AT) originating from atrial appendage in 30% children with AT can often lead to tachycardia cardiomyopathy (TIC) resulted from the AT which is often incessant. Traditional radiofrequency ablation performed at atrial appendage usually is challenging with low success rate, high recurrence rate, and significant risk of pericardial tamponade. This article reports for the first time in China the successful treatment of a 10-year-old boy (34.5 kg) with AT originating from left atrial appendage combined with TIC using a novel contact force sensing pulsed field ablation (PFA) catheter. The clinical manifestations of the child were persistent palpitations with reduced heart function, which was detected by echocardiography with left ventricular end-diastolic diameter (LVEDD) of 48mm and left ventricular ejection fraction (LVEF) of 46%. The focal origin of the AT was confirmed at the distal position of left atrial appendage by the characteristics of 12-lead ECG and local activation time (LAT) map with 3-dimentional mapping system. During the procedure, the AT was successfully terminated using the novel PFA catheter with 1800V pulse-field energy at the contact force of about 20g and the total time of ablation application was 20s. The 1-month follow-up after the operation showed no recurrence of AT, significant improvement in cardiac function (LVEF 58%, LVEDD 44mm), and no complications occurred. This case report preliminarily demonstrated that novel contact force sensing PFA catheter provided a safe and effective strategy for minimally invasive treatment of refractory pediatric arrhythmia originating from atrial appendage by realizing three technical advantages: precise ablation in children's narrow cavity of atrial appendage, ultra-short ablation time and real-time contact force feedback. This technological breakthrough is of great significance for promoting the development of interventional treatment for complex arrhythmias in children.

Cite this article

LIU Fuqiang , WANG Chuan , DUAN Hongyu , LI Yifei , MA Fan , WANG Fang , ZHOU Kaiyu , HUA Yimin . Pulsed field ablation for atrial tachycardia originating from left atrial appendage in children: a case report[J]. Journal of Clinical Pediatrics, 2025 , 43(10) : 787 -791 . DOI: 10.12372/jcp.2025.25e0859

References

[1] Ko JK, Deal BJ, Strasburger JF, et al. Supraventricular tachycardia mechanisms and their age distribution in pediatric patients[J]. Am J Cardiol, 1992, 69(12): 1028-1032.
[2] Dieks JK, Müller MJ, Schneider HE, et al. Catheter ablation of pediatric focal atrial tachycardia: ten-year experience using modern mapping systems[J]. Pediatr Cardiol, 2016, 37(3): 459-464.
[3] Zhang Y, Li XM, Jin Y, et al. Surgical and ablation therapies for atrial appendage tachycardia in children[J]. JACC Clin Electrophysiol, 2025, 11(2): 400-407.
[4] Kang KT, Etheridge SP, Kantoch MJ, et al. Current management of focal atrial tachycardia in children: a multicenter experience[J]. Circ Arrhythm Electrophysiol, 2014, 7(4): 664-670.
[5] Yang Q, Ma J, Zhang S, et al. Focal atrial tachycardia originating from the distal portion of the left atrial appendage: characteristics and long-term outcomes of radiofrequency ablation[J]. Europace, 2012, 14(2): 254-260.
[6] Batista Napotnik T, Polaj?er T, Miklav?i? D. Cell death due to electroporation - A review[J]. Bioelectrochemistry, 2021, 141: 107871.
[7] Reddy VY, Gerstenfeld EP, Natale A, et al. Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation[J]. N Engl J Med, 2023, 389(18): 1660-1671.
[8] van Zyl M, Ladejobi AO, Tri JA, et al. Reversible atrioventricular conduction impairment following bipolar nanosecond electroporation of the interventricular septum[J]. JACC Clin Electrophysiol, 2021, 7(2): 255-257.
[9] Chun KJ, Miklav?i? D, Vlachos K, et al. State-of-the-art pulsed field ablation for cardiac arrhythmias: ongoing evolution and future perspective[J]. Europace, 2024, 26(6): euae134.
[10] Urbanek L, Chen S, Bordignon S, et al. First pulse field ablation of an incessant atrial tachycardia from the right atrial appendage[J]. J Interv Card Electrophysiol, 2022, 65(3): 577-578.
[11] Rossillo A, Borio G, Vittadello S, et al. Focal atrial tachycardia arising from left superior pulmonary vein in a pediatric patient, safely treated by pulsed-field ablation[J]. J Cardiovasc Electrophysiol, 2023, 34(8): 1764-1767.
[12] Hua J, Xiong Q, Kong Q, et al. A novel contact force sensing pulsed field ablation catheter in a porcine model[J]. Clin Cardiol, 2024, 47(2): e24220.
[13] Reddy VY, Petru J, Funasako M, et al. Coronary arterial spasm during pulsed field ablation to treat atrial fibrillation[J]. Circulation, 2022, 146(24): 1808-1819.
[14] Phlips T, Verhaeghe L, Antole N, et al. Pulsed field ablation using a focal contact force catheter allowed successful ablation of a focal right atrial tachycardia in the proximity of the phrenic nerve[J]. HeartRhythm Case Rep, 2023, 9(7): 434-436.
Outlines

/